Technical specifications.
- Memory type
- HBM3
- GPU memory
- 80 GB
- Memory bandwidth
- 3.35 TB/s
- Maximum TDP
- Up to 700 W
Configurable; the complete system power budget is separate.
- Form factor
- SXM module
- Host interface
- PCIe Gen5; 128 GB/s
This is an SXM module, not a PCIe add-in card.
- GPU interconnect
- NVLink: 900 GB/s
- Workload focus
- AI training, inference and HPC
Ordering considerations.
- Confirm the exact server GPU qualification, chassis, risers, power cables, cooling and firmware before ordering. Your complete configuration will be confirmed with the quotation.
- Cooling and module integration are system-specific. The exact cooling assembly and OEM option number remain to be confirmed.
Compare the exact variants.
Memory capacity and bandwidth below are per GPU. A bridge group does not turn several cards into a single card, and quoted module power is not the complete server power budget.
NVIDIA data-center GPU variant comparison| GPU variant | Memory | Bandwidth | Maximum power | Connection |
|---|
| H100 SXM 80GB | 80 GBHBM3 | 3.35 TB/s | Up to 700 W | NVLink: 900 GB/s |
|---|
| H100 PCIe 80GB | 80 GBHBM2e | 2,000 GB/s | Up to 350 W | NVLink: up to 600 GB/s |
|---|
| H200 SXM 141GB | 141 GB per GPUHBM3e | 4.8 TB/s | Up to 700 W | NVLink: 900 GB/s |
|---|
| H200 NVL 141GB | 141 GB per GPUHBM3e | 4.8 TB/s | Up to 600 W | 2- or 4-way NVLink bridge: 900 GB/s per GPU |
|---|
| RTX PRO 6000 Server | 96 GBGDDR7 with ECC | 1,597 GB/s | Up to 600 W (configurable) | NVLink not supported |
|---|
H200 specifications are preliminary and subject to change. H100 PCIe here is the 80 GB HBM2e version, not H100 NVL 94 GB. RTX PRO 6000 is the air-cooled Server Edition, not a Workstation or Max-Q card.
SXM or PCIe: start with the platform.
SXM GPU systems
H100 SXM and H200 SXM are modules for an integrated GPU subsystem. The carrier, interconnect, heatsink or liquid-cooling assembly, firmware and system power design form part of that platform. An available PCIe slot is not an installation path for an SXM module. For replacement enquiries, provide the original server model, service identifier and full GPU assembly part number. Confirm whether the supplied item is a module, a service assembly or a complete system.
PCIe accelerator servers
H100 PCIe, H200 NVL and RTX PRO 6000 Server Edition require a supported server configuration. Check the riser and slot position, front GPU bay, supplemental power cable, power supplies, fans and airflow. Passive cards depend on the server cooling system. For an upgrade, the installed CPU generation and cooling package can restrict the GPU options even when the card appears to fit.
Check more than card length.
Bracket & clearance
A nominal form factor does not describe every projection. Allow for the I/O bracket, retention hardware, extension pieces, power connector and cable route. Measurements for a bare board must not be substituted for a complete service assembly.
Power & temperature
Maximum GPU power is only one part of the system budget. The server configuration, CPU count, redundancy policy and input voltage determine the power supply arrangement. Confirm inlet temperature, altitude limits and the correct high-performance fans.
Interconnect & quantity
NVLink bridge requirements differ by GPU variant. Use the appropriate bridge and supported card spacing. A server with eight GPU positions does not imply a single eight-card bridge group, and the maximum GPU count does not approve every possible intermediate population.
Keep OEM option numbers separate.
A NVIDIA GPU model describes the accelerator family and variant. Dell, HPE and Lenovo may supply that accelerator under their own option or service part numbers, with different brackets, cables, firmware requirements and installation kits. Matching the GPU name alone is not enough to substitute one OEM option for another. Send both the server identity and the full existing part number when requesting a replacement; our quotation will identify the proposed item and included accessories.
Prepare your GPU enquiry.
Share the exact GPU variant, required quantity, new-build or upgrade requirement, target server and current hardware configuration. Include your rack power, cooling conditions and delivery destination. If the purchase replaces an installed component, a clear label photo and the original OEM part number help avoid a mismatched option. Product images are for presentation; condition, supplied accessories, availability, lead time and delivery terms are confirmed in the formal quotation.